measuring range (MB):
overload limit (ÜL):
burst pressure (BD): |
1 1.6 2.5
4 6 10 16
25 40 60 100
160 250 400
600
2 3.2
5 8 12 20
32 50 80 120 200
320 500 800
1.200
5 10 10
17 34 34 100 100 400
550 800 1,000 1,200 1,700 2,400 |
| output
signal: |
4 to 20mA, 2-wire, RA (Ohm) <
(UV(V) - 8V) / 0.02A
0 to 10V, 3-wire, RA > 10 kOhm
(other output signals upon request) |
| auxiliary
energy: |
8 to 30VDC (for output 4 to 20 mA)
14 to 30VDC (for output 0 to 10V) |
|
accuracy:
* |
<1.0% FS (optional. <
0.5% FS)
(*=non-linearity, hysteresis, zero point and scale error
incl.. corresponding with error of measurement per IEC 61298-2
Sensor adjusted in vertical mounting position with lower pressure connection)
|
| non-linearity: |
<0.6% FS (optional <0.3% FS) |
| zero offset: |
<0.5% FS (typ.), <0.8% FS (max.)
optional: <0.15% FS (typ.), <0.4% FS (max.) |
| hysteresis: |
<0.16% FS |
| repeatability: |
<0.1% FS |
| long-termed drift: |
<0.1% FS (according to IEC 61298-3) |
|
response time:
t90 |
<4 ms |
|
perm. temperature of meas.media: |
0°C to +80°C (optionally -30°C
to +85°C) |
|
ambient temperature: |
0°C to +80°C (optionally -20°C to +80°C) |
|
storage temperature: |
-20°C to +80°C |
|
temperature compensated area: |
0°C to +80°C |
|
temperature error in comp. area: |
<1.0% FS (typ.), <2.5% FS (typ) |
|
material: |
Parts coming into contact
with pres. media
- pressure connection: 316 L
- pressure sensor: 316 L (as of 10bar
rel. 13 to 8 PH)
- housing:
316 L |
| pressure connection: |
G 1/4A (= 0,635 cm), DIN 3852-E with NBR
sealing |
|
protection rating: |
IP65 resp. IP67 with cable |
|
electric connection: |
elbow-type plug acc. to DIN
43650 or connection cable, cable length 1.5m |
|
electric protection: |
reverse voltage and short-circuit protection |
|
weight: |
approx. 80g |
Pressure measuring transducer for relative pressure (zero output at atmospheric pressure), optionally absolute pressure, basic price