Scaleable humidity and
humidity/temperature transducer
GHTU -1R MP
sensor tube at the side,
probe length FL=50mm
GHTU-1K MP
sensor tube at the side,
probe length FL=220mm
GHTU-2K MP
sensor tube pointing downwards,
probe length FL=220mm
GRHU-1R MP
sensor tube at the side,
probe length FL=50mm
GRHU-1K MP
sensor tube at the side,
probe length FL=220mm
GRHU-2K MP
sensor tube pointing downwards,
probe length FL=220mm
Description:
The latest generation of our humidity/temperature transducer offers even greater
possibilities to compensate the special sensor characteristics due to the
brand-new
microprocessor technology. Regarding precision, temperature stability and
functionality a new dimension has been reached. The transducer can be used for almost all
applications due to the different types (e.g. wall or channel mount, with
separated probe or with heat absorption hat) and the wide temperature range (electronic:
-25°C..+50°C; sensor: -40..+120°C).
Pict.1: type -1R
Pict.2: Design -2K
simultaneous measuring of humidity and temperature
On-site display for humidity and temperature (alternating)
humidity and temperature output range freely selectable
offset and slope for humidity and temperature digitally
adjustable
output signals for humidity and temperature are
electrically isolated
available output signals: 4-20mA, 0-1V or 0-10V (others
upon request)
Min-/max-value memory
Pict.2: Design -1K
Specification :
Meas. ranges:
Humidity:
0.0..100.0% r.H (temperature compensated);
Temperature:
-40.0..120.0°C resp. -40.0...248°F
Recommended range:
20.0..80.0% r. H. (standard) at option high humidity -HO: 5.0..95.0% r.H)
Display range
options:
alternative display and output value instead of humidity measuring value
FK: Wet bulb temperature -27.0..+60.0°C
TP:
dewpoint-temperature -40.0..+60.0°C
EP: Enthalpy
-25..999,9kJ/kg
FG: Atmospheric humidity 0.0..640.0
g/kg
Accuracies:
(at nominal temperature =25°C)
Indication humidity:
+ 1% linearity, + 2% hysteresis (at recommended range)
Indication temperature: + 0.4% of meas. value
+ 0.2°C
add. output signal : each + 0.2% FS
Temperature
compensation:
automatically
Min-/Max-value:
the min- and
max-value are memorized
Output:
4-20mA (2-wire), resp.
2*4-20mA (2-wire); as option also 0-1V or 0-10V (3- or 4-wire available) -
other output signals upon request
Scaling:
by entering display values for
4mA (resp. 0V) and 20mA (resp. 1V/10V) output
Connection:
4-20mA (2-wire) - output signals are electrically isolated
one from each other
at option AV01, AV10: 0-1 (10) Volt (3-wire) - output signals are not
electrically isolated one from each other
at option AV01G, AV10G: 0-1 (10) Volt (3- or 4-wire) -
output signals are electrically isolated one from each other
auxiliary
energy:
12..30V DC resp. 18..30V DC
for output 0-10Volt
Reverse voltage protection:
50V permanently
Permissible impedance:
(at 4-20mA): RA [Ohm]=(UV [V]-12V)/0.02A
Permissible load:
at 0-1(10) Volt: RL
>3000 Ohm
Display:
approx. 10mm high, 4-digit
LCD, alternating humidity and temperature display
Working temperature:
-25 to 50°C
(electronics); Sensor head and tube: -40..100°C - for short time up to
120°C
Storage temperature:
-25..70°C
Relative
humidity:
(electronics): 0 to 95% r.H. (non condensing). If there is a risk of
condensation due to temperature changes, please use our encapsulated or
lacquerded types (optionally available)
Housing:
ABS (IP65)
For outdoor use:
heat absorption head (p.r.t. options)
Sensor
tube:
tube 14mm diameter, with removable screw-type protection cap
Sensor
length:
50mm resp. 220 mm (standard)
- other lengths optionally available
Available sensor
lengths: "FL": 300mm, 400mm, 500mm
At
temperatures exceeding the working temperature of the electronics care should be
taken
that the electronics keep within the specified range, a separated probe might be used (optionally available)
Mounting:
with mounting holes for
wall mounting (accessible after cover has been removed)
or by means of plastic
tube clamps, additional wall support for direct mounting to channels, etc..
Mounting hole
distance for wall mounting: 70x50mm (WxH)
Fixing screws for
wall monting: max. shaft-diameter: 4mm
Electric connection:
elbow-type plug acc. to DIN 43650 (IP65), max. wire cross section:
1.5mm², wire diameter from 4.5 to 7mm
Options:
-HO:
high humidity sensor for humidity measuring <20%r.H. and >80% r.H.
when ordering, please make sure to specify main measuring range!
-FK, TP, EP, FG
Optional display range
-LACK :
Encapsulated PC-board on both sides
- FL300, FL400,
FL500:
longer sensor tube - no interim length possible: 300, 400 or 500mm
-AV01 :
Output signal 0-1V (note for GHTU: output signals are not electrically isolated
one
from each other)
-AV01G :
output 0-1V (for GHTU with electric isolation)
-AV10 :
output signal 0-10V (note for GHTU: output singnals are not electrically
isolated one from each other)
-AV10G :
output 0-10V (for GHTU with electrical isolation)
-KABEL :
with separated sensor tube. Sensor tube (diam. 14x68mm) connected to device via
1m teflon cable
-SHUT :
heat sbsorption hat / weather protection shield. The heat absorption hat is
especially designed for measurements in the open air. The measuring results that
can be archived will not be influenced by either sun or rain
Accessories :
Spare protection cap:
with stainless
steel gauge (105µ mesh size) - for standard and high humidity use
Bronze filter:
not for use in high
humidity use
Order
examples:
GHTU-2K-MP-AV10-FL300
GRHU-MP-KABEL-HO
digital humidity-/temperature measurement transducer with brand new microprocessor system, basic price
containing on-site display, digitally adjustable zero point, min-max-memory etc..
For the usage in conditioning of air, heat and climate, control processes in drying of goods, meterology, controlling and regulating in storage rooms and in cleanrooms etc...
Please order separately:
Please note in the textbox the sensor connection and measuring range required
= data sheet as *.pdf
= instruction manual as *.pdf
deutsche Beschreibung
Price of the basic article, German V.A.T. incl
:
EUR
245.50
The net price of the basic article GHTU...MP
is:
EUR
206.3
1K - Sensor tube sideways, probe length 220mm
1R - sensor tube sideways, probe length 50mm
2K- sensor tube downwards, probe length 220mm