Specification:
|
|
Measuring inputs: |
Universal input for:
|
|
|
Normalized signal |
4-20mA, 0-20mA, 0-1V, 0-2V, 0-10V, 0-50mV |
|
resistance thermometer |
Pt100(3-wire), Pt1000 (2-wire) |
|
thermocouples: |
Type J, K, N, S, T |
|
frequency, rotational speed:
|
TTL-Signal, switching contact |
|
Counter up/down:
|
TTL-Signal, switching contact |
|
serial interface: |
|
|
Measuring rate:
|
approx. 100 meas. /sec. (for norm. signal) resp. approx. 4 meas./sec. (for
temperature and frequency) |
|
Measuring- resp. display ranges, resolution:
|
Temperature:
|
(display unit selectable: °C or °F ) |
|
Pt100: |
-200..+850°C resp. -70.0 ... +250.0°C |
|
Pt1000: |
-200 ... +850°C |
|
Typ J:
|
-170 ... +950°C resp. -100.0 ... +300.0°C |
|
Typ K:
|
-270 ... +1372°C resp. -70.0 ... +250.0°C |
|
Typ N:
|
-270 ...+1350°C resp. -100.0 ... +300.0°C |
|
Typ S:
|
-50 ... +1750°C |
|
Typ T:
|
-270 ...+400°C resp. -70.0 ..+200.0°C |
|
Norm. signals:
|
-1,999 ... 9,999 digit; scale freely adjustable |
|
- recommended range:
|
< 2,000 digit |
|
Frequency:
|
0.000 Hz ... 10kHz, display freely selectable |
|
rotational speed:
|
0.000 U/min ... 9999 U/min
selectable prescaler:
1-1000
|
|
Counter up/down:
|
countervalue remains on power
loss
0...9999 (10 Mio. with
prescaler)
pulse frequency : <10kHz
selectable prescaler:
1-1000
|
|
Serial interface:
|
displaying from
values coming via the serial interface
|
|
Accuracy:
|
(at nominal temperature = 25°C) |
|
Norm. signal:
|
<0.2 % FS + 1 digit
(for 0-50mV: <0.3% FS + 1Digit) |
|
resistance thermometer:
|
<0.3% FS +1 digit |
|
Thermocouples: |
<0.3%FS +1 digit /(for
Typ S: <0.5%FS + 1Digit) |
|
Point of comparison: |
+1°C |
|
frequency, rotational speed,
counter:
|
<0.1% FS + 1 digit
|
|
analog output: (optional) |
free scalable analog output 4-20mA, 0-20mA or 0-10V |
|
Display:
|
approx. 13 mm high, 4-digit red
LED-display
|
|
min-/max-value memory:
|
the max- and min value will be
stored
|
|
Interface:
|
serial interface, electrically
isolated, EASYBUS-compatible
|
|
Power supply for sensor:
|
integrated isolated power
supply for measuring transducer: 18V DC + 5%, 20mA
|
|
Miscellaneous:
|
permanent self-monitoring,
digital filter function, measuring range boundary (limit)
|
|
power supply:
|
230 V AC, 50/60 Hz (standard)
optionally 12/24 V DC or
24/115 V AC possible
|
|
Power consumption:
|
approx. 3 VA
|
|
Operating temperature:
|
-20..+50°C
|
|
relative humidity:
|
0 to 80 % r. H. (non-condensing)
|
|
Storage temperature:
|
-30 to +70°C
|
|
Housing:
|
standardized rack type housing 48x96mm
(front frame)
Installation depth: approx. 115mm (incl. Screw-type/plug-in terminals)
|
|
Panel mounting:
|
by fixing clamps
Panel cutout: 43.0 x 90.5 mm (HxB) |
|
Electrical connection:
|
via screw-type / plug-in
terminal
cable diameters from 0.14² to 1.5²
|
|
Protection class:
|
front side IP54, with optional
sealing IP 65
|
|
Electromagnetic immunity (EMV):
|
EN 61326 (appendix A, class B) |
|
Options:
(against upcharge) |
|
other power supply:
|
-12 V DC1
- 24 V DC1
- 24 V AC
-115 V AC
|
|
output:
|
-AAG420: analog output 4-20mA
-AAG020: analog output 0-20mA
-AAG010: analog output 0-10V
1at analog output with option 12 V DC or 24 V DC additional
surcharge
|
Universal measuring device - easy operability - high accuracy - economic price, basic price
Follower of GIA 1002Pt100 and GIA 1002NS