Low Cost conductivity measuring device GLF 100 - Greisinger
electronic
universal conductivity
measuring device
specialties:
the measuring cells:
3 conductivity measuring ranges
low power consumption
automatic measuring range change-over
min/max-value memory
automatic temperature compensation via
integrated temperature sensor
hold function
adjustable
The measuring cells are designed without any compromise.
By the openings of the sensors the electrodes are well washed around
and well-protected against mechanical influences.
The integrated temperature sensors response very quickly.
Compared with more simple electrode types the measurements are
much faster and much more precise.
area of application:
Graphite used as material for the electrodes
makes the applicability up to 100mS/cm
possible - a must have for seawater analytics!
picture follows within short time!
fresh and sea water aquaristics
fish farming / water monitoring
drinking water monitoring, etc.
measuring ranges:
conductivity:
0 to 2,000 µS/cm
0.00 to 20.00 mS/cm
0.0 to 100.0 mS/cm
temperature:
-5,0°C to +100,0 °C
TDS:
0 to 2.000 mg/l
salinity:
0.0 to 50.0 g/kg
accuracy:
(+ 1
digit, at
nominal temperature = 25°C)
conductivity:
+ 0.5% of meas. value +0.5% FS
temperature:
+ 0.3°C
temperature compensation:
off:
deactivated
nLF:
non-linear, acc. to EN 27888
reference temperatures: +20°C and +25°C
measuring cell:
2-pole measuring cell, diameter 12 mm
(graphite)
with integrated temperature sensor
display:
approx. 11mm high, 4 1/2-digit
LCD-display
working conditions:
device:
-25°C to +50°C, 0 to 95% r.h. (non-condensing)
measuring cell:
-5°C to +80°C (for short-time: +100°C)
power supply;
9V battery, type 6F22 (in scope of supply)
power consumption:
<1.5mA
housing:
impact resistant ABS, plastic foil keyboard,
transparent panel, front side IP65
dimensions (device):
110 x 67 x 30mm (H x W x D)
weight:
approx. 155g
device functions:
hold function:
by pressing a key the current measuring value
is
"frozen"
min-/max-value memory:
the min. and max. measured value is stored
power-off function:
device turns off after a certain time, if it is
not used
(adjustable: 1-120min or deactivated)
universal conductivity measuring device
applications:
fresh and sea water aquaristics
fish farming / water monitoring
drink water monitoring etc.
Please order the following works calibration certificates separately:
Please order the following option and accessories separately:
= data sheet as *.pdf
= instruction manual as *.pdf
deutsche Beschreibung
Price of the basic article, German V.A.T. incl
:
EUR
163.00
The net price of the basic article GLF 100
is:
EUR
136.97