|
Software:
GMH 3000.DLL
Windows-functional library for
interface communication GMH-device <---> PC,
to write your own programs. |
|
RECORDING - LONG-TIME MONITORING
-LARGE-DIGIT
DISPLAYIn connection with a PC this software makes up a
low-price and comfortable multi-channel acquisition program for measuring
data. The software supports the following measuring systems, level
converter and measuring components.
|
Recorder function

|
| Meas. system: |
Level converter: |
Components: |
| EASY-BUS |
EBW 1, EBW 60, EBW 240, EB 2000, |
EASY-LOG, EBT, EBH, EBN |
| GRS 485 |
GRS 485 |
GIA 10, GIA 1000..., GIR 1002... |
| GMH-devices |
GRS 3100, GRS 3105 |
| A combination of the various measuring systems
is not possible! |
|
|
General advise:
|
|
Data are read via the serial interface 'COM 1', 'COM 2',
'COM 3' or 'COM 4' of your personal computer - no module slot at the PC
required!
In combination with a standard modem and an EASYBUS modem a remote
application can be set up.
Our EBS 9M software includes 2 functional modules for
"recording/large digit
display" as well as a SETUP programm to select the language required.
|
|
Module "Recording/large-digit display"
|
|
|
Measuring values displayed as y/t-diagram or digital indication
adjustable scan rate: 0.5s, 1s,
2s, 5s, 10s, 30s, 1min, 2min, 5min, 10min,
30min, 1h, 2h, 5h
t-axis (time):
- display in minutes, hours or days
- automatic scaling
- scrolling function
y-axis (measured value):
- automatic scaling
- adjustable display range
- axis identification possible
Miscellaneous:
- switch over from y/t-diagram to digital display
- entering of a comment line
- automatic system initialisation
- individual legend for each diagram
- storing of measuring values - recording time up to several years
- adjustable start and stop conditions
|
configuration as large-digit display resp. combined
recorder/large-digit display also possible!



|
Module "data display"
|
|
t-axis (time):
- automatic scaling can be switched on/off
- display range freely selectable
- grid selectable
y-axis (meas. value):
- automatic scaling can be switched on/off
- display range freely selectable
- grid selectable
Miscellaneous:
- line width and colour freely selectable
- identification of meas. points can be selected
The "data display" module can be used together
with the modules "large digit display/recorder". Therefore, it
is possible any time to check the measuring values already stored without
having to interrupt the on-going recording process.
The EBS 9M stores all settings and measuring values in the ASCII code
so that they can be read and processed by almost all standard software
programs (e.g. Excel, Quattro Pro etc.) |
Data display

|
System requirements:
|
|
- as of Pentium 100
- 8 MB RAM
- approx. 7 MB free on hard disk
- CD-ROM-drive
- VGA-graphics card with resolution 640 x 480, 800 x 600 or better
- Windows 95, 98, NT4.0 or better
- serial interface
- mouse
Update EBS 9M: for registered users with declaration of serial
number of original version
|
configuration of connected devices

|
|
Windows-software for the setting, data read-out and printing of all
data (diagrams and tables) stored by devices of the GMH-series with
logger function. |
|
General description:
|
|
| With GSOFT 3050 you are able to operate the logger function
of the GMH3000-hand-held series. The logger recordings can be started,
stopped, read in and displayed. It is also possible to operate several
instruments simultaneously and to display their date in mutual diagrams. Data
will be read via the serial interfaces 'COM 1', 'COM 2', 'COM 3' or 'COM
4' of your PC - a PC slot has not to be used.
The software is bilingual (german/english), the language can be
selected simply in the programme.
The GSOFT 3050 offers, among other things, the following functions:
- Display of the GMH-information
Both the GMH-time and the logger information will be constantly
displayed in the GMH-information window; current measuring values can
be called up by clicking a button.
- Setting of the alarm function
simple alarm function setting for GMH-devices.
- Operation of the logger function
simple selection of the logger function (cyclic or manual),
setting of cycle time, logger recording start and stop, read-out of
logger data.
- Diagram display of logger data
The logger data can be displayed in form of a diagram. Itis posible to
display various measuring sequences in one dagram.
The diagram offers the following functions:
- display including real-time axis
- Zooming of display view
- Display of legend can be switched on/off
- marking of measuring points can be aded/deleted at any time
- a new/existing measuring sequence can be added/deleted at any
time
- Logger data print-out
Data can be printed as tables (complete measuring sequence or
limited area) or as diagram (in accordance with the current diagram
window
- Memorizing of logger data
The logger data can be saved in files and, therefore, called up
again at any given time.
- Export of logger data to ASCII (text) file format
- Memorizing of windows
Data and diagram windows can be placed at any desired position on the
screen. The setup of the windows can be stored as "view".
When reloading a "view" the window setup will be restored.
|


|
System preconditions:
|
|
- as of Pentium 100
- 32 MB RAM
- approx. 20 MB empty space on the hard disk memory
- CD-ROM-drive
- VGA-graphics with a resolution 800 x 600 or better
- Windows 95, 98, NT4.0 or better
- serial interface
- interface converter GRS 3100 or GRS 3105
- mouse (recommended) |
|
Update GSOFT 3050: for registered users with declaration of serial
number of original version
16-Bit-Windows-function library for interface communication GMH-device - PC, to write your own programms
= data sheet as *.pdf
deutsche Beschreibung
Price of the basic article, German V.A.T. incl
:
EUR
71.90
The net price of the basic article GMH3000DLL
is:
EUR
60.42
|