specification: |
|
max. display range: |
-19999 to +19999 Digit |
|
measuring range/overload/resolution: |
depends on probe connected |
|
pressure units:
|
mbar, bar, Pa, kPa, MPa, mmHg,
PSI, m, can be selected |
|
accuracy: |
(device) (at nominal temperature = 25°C) ±0.1 %FS +1 digit |
|
probe connection: |
6-pin screened lockable Mini-DIN-sockets for GMSD-sensors
automatic probe detection and corresponding adjustment of measuring range |
|
display: |
two 4 1/2-digit LCD displays |
| operating elements: |
6
push buttons |
| working
temperature: |
GMH 3151: -25°C
to +50°C;
GMH 3151-EX: -10°C to +50°C |
| relative humidity: |
0 to 95% r.h. |
|
Interface: |
serial interface or AAG direct connection to RS232
or USB interface of a PC
via interface converter USB 3100 or GRS 3100, GRS3105 |
| analog
output: |
0-1V, freely
adjustable (resolution 12bit) |
| power
supply: |
9V-battery, d.c.
connector
suitable 9V-battery type IEC 6F22 (in scope of supply),
d.c. connector for external 10.5-12V direct voltage supply (suitable
power supply: GNG 10/3000) |
| sensor
adjustment: |
digital offset
and scale input |
| power
consumption: |
max. 1.6 mA (slow
mode), max. 7mA (fast = 1000 Hz) |
| battery changing display: |
'bAt' |
| power-Off-function: |
1 to 120 min (can also
be deactivated) |
| housing
dimensions: |
142 x 71 x 26 mm
impact-resistant ABS plastic housing, front side IP65,
integrated pop-up clip for table top or suspended use (not at GMH
3151-EX) |
| weight: |
approx. 155 g, Ex-construction approx. 190 g (bag incl.) |
|
tare function: |
display value and the min/max values memorized can
be set to zero |
| hold function: |
by pressing a
button the current measuring value will be memorized |
|
Min-/Max value memory: |
memorizing of max and min values |
|
averaging function: |
integrates the measuring values during a selectable
period of time and calculates the average display value then |
|
peak value memory (peak detect) |
in the min/max value memory non-filtered pressure peaks >1 msec will be registered |
| measuring cycle: |
3 measuring
functions are available |
| "slow" |
= 4 measurements / sec. |
| "fast" |
>1000
measurements /
sec. (with filter) |
|
"peak-detect" |
>1000 measurements /
sec. |
| low
power logger mode: |
(only in
measuring cycle "slow") Only one measurement is carried out at
the end of the logger cycle set
The battery life is prolonged considerably. For long-termed recordings (e.g.
tightness). |
| logger functions: |
manually: |
99 data sets |
|
cycle: |
10000 data sets (max. 64 recording sequences) |
|
adjustable cycle time:
|
1 to 3600 sec. |
logger is started and stopped via the keyboard or
interface.
(comfortable read-out and display software (GSOFT 3050) available
optionally against surcharge) |
|
Min-/Max alarm: |
the measuring value is constantly monitored whether they
are
remaining within the min/max limits set
(can be deactivated) |
| alarm: |
3 different
alarm settings |
| "off" |
alarm function switched off |
| "on" |
visual alarm via display,
interface alarm, alarm sound via integrated signal-horn |
| "no.So." |
visual alarm via display
and interface alarm |
|
controlling function: |
by means
of the switching module GAM 3000 (optionally against surcharge)
electric equipment can be switched on/off or alarm memorized |
|
real-time clock: |
clock with date and year integrated in the device |
| SeaLevel-correction: |
when connecting
an absolute pressure probe the barometer air pressure can also be
indicated adjusted
to sea level "zero". (air pressure improvement by entering the meters
above sea level "zero") |
Only ONE portable device for a all kinds of pressure and for any measurement ranges, with additional functions compared with GMH 3110 (logging function, alarm function, real-time clock...)
Lose device without sensors and accessories
Follower of GMH 3150