Categories



The complete product assortment of the GSG Geologie-Service GmbH

According to your requirements we are arranging together with
you the optimum system for your individual application
Please describe us your requirements, our team will contact you as soon as possible.

You are reaching us by e-mail: 
mail@geologie-service.de
or by:
Phone: +49 (0)931/30 40 8-0
Fax: +49 (0)931/99105 90



GMH 3210 - Details

Home --> Temperature and Humidity --> Temperature Measurement + Accessories --> Digital Thermometer


 

Digital precision quick-response thermometer with freely adjustable analog output

GMH 3210        

Battery / mains operation for plug-in probes, data hold function, freely adjustable analog output 0 to1V

Applications:

Suitable for all quick-response, high-precision temperature measurements. Analog output 0-1V for recorder connection, min/max. memory.

Special features:

  • freely adjustable analog output or serial interface, selectable by menu setting
  • Min/Max-value memory, hold function
  • Correction of meas. value for surface measurement can be switched on/off.
  • Zero-point offset entry
  • 5 different thermocouples selectable (Type K, J,N, S or T) 
  • Battery and d. c. operation
  • Automatic power off, selectable within 1 to120min, or permanent operation
  • Low power consumption of ca. 0.3 mA (with included standard battery ca. 1,000 hours of operation)
  • Display in °C or  °F (selectable)
  • ready (for up to  5 instruments of the GMH3000-series can be connected to a single serial PC interface)

(without accessories)

 

Specification:

Thermocouples:

Type K, J, N, S, T (acc. to DIN EN 60584)

Measuring ranges:

(extract)

 

Type K: (NiCr-Ni)

-65,0..+300.0°C resp. -220...+1372°C

(-85,0 ... +572,0°F resp. -364 ... +2500°F)

Type S: (Pt10Rh-Pt) -50 ... +1768°C (-58 ...+3214°F)
Type N: (NiCrSi-NiSi)

 

-100,0 ... +380,0°C bzw. -200 ... +1300°C

(-148,0 ... +482,0°F resp. -328 ... +2372°F)

 

Resolution:

0.1°C or 1°C  (0.1°F or 1°F) 

 

Accuracy:

(extract)

 +/- 1 Digit at nominal temperature

 Type K: 

-65.0 to 300.0°C  : + 0.03% of meas. val.. + 0.05% FS

-220 to 1372 °C: + 0.08%  of meas. val. + 0.1% FS

Type S: 

-50 to 1768°C:  + 0.1% of meas. val. + 0.1% FS

Type N:

-100,0 ... +380,0 + 0.03% of meas. val.. + 0.05% FS

-200,0 ... +1300,0 + 0.08% of meas. val.. + 0.1% FS (T>-100°C)

-200,0 ... +1300,0 + 1°C of meas. val.. + 0.1% FS (T<-100°C)

Temperature drift:

0.01%/K

 

Point of comparison:

+ 0.3°C

 

Analog output:

0 to 1V, freely adjustable, resolution 13 bit, accuracy 0.05% at nominal temperature

Nominal temperature:

25°C

 

Working temperature: -25 to +50°C

 

Relative humidity:

0 to 95% (non-condensing)

 

Storage temperature:

-25 to +70°C

 

Probe connection:

jacks for the flat pin plug for the simultaneous connection

Display:

2 four digit LCDs for temperature,  min/max-values, hold function etc. as well as additional functional arrows

 

Min/Max-value memory:

Memorizing of max. and min. values 

 

Hold function:

By pressing a button the current values are memorized.

 

Push buttons:

6 membrane keys for ON/OFF-switch, feature selection,  min-max-value memory, hold-function

 

Power supply: 9V battery, Type IEC6F22 (included) as well as additional d. c. connector (internal pin diam. 1.9 mm) for external 10.5-12V direct voltage supply. (suitable power supply: GNG 10/3000)
Low battery warning:

  ! and "bAT"

 

Power consumption:

ca. 0.3 mA

 

Auto-Off-Function::

By activating the auto off function the device is automatically switched off, if its interface and keypad is not attended for a longer time (selectable 1 to120min) 

Interface:

serial interface (choice between interface or analog output operation is done via menu), direct connection to RS232 interface or USB3100 interface of a PC via electrically isolated interface adapter GRS 3100 / GRS 3105.

 

Dimensions:

142x71x26 mm (HxWxD) Impact-resistant ABS plastic housing, membrane keyboard, transparent panel. Front side IP65, integrated pop-up clip

 

Weight:

approx. 155g

 

Special applications:

 

Compensation for surface measurements:

A compensation value (to compensate for loss when transferring heat from the meas. object to the probe) can be set and switched on/off for surface measurements, if required.

Zero-point offset entry:

By entering the offset temperature the parameter can be moved parallely to the calibration graph.

 

 


Accessories: 

GNG 10/3000

net power supply

GB 9V spare battery
GKK 3000 case with punched lining
GKK 3100 case with foam lining
GKK 3500 large case with punched lining
ST-N1 device protection bag with 1 right angled hole
ST-N2 device protection bag with 2 right angled holes
GRS 3100 interface converter with 1 connection
GRS 3105 interface converter with 2 connections
USB 3100 interface converter to USB
EBS 9M software for transmission
probes type K (up to 1150°C)
probes type N (up to 1300°C)
probes type S (up to 1600°C)


Digital precision quick-response thermometer with freely adjustable analog output or serial interface (sensor not incl.)

Please order the following accessories separately:

  Please order furthermore separately:



= data sheet as *.pdf

= instruction manual as *.pdf

deutsche Beschreibung

Price of the basic article, German V.A.T. incl : EUR 146.50


The net price of the basic article  GMH 3210 is:  EUR 123.11 




News