GMH 3530 - Details

Home --> pH- and Redox-Devices --> Devices


The new generation of pH-/redox-/temperature meas.devices!

- Double display for pH or redox and temperature

- Redox mode allows for automatic conversion to a hydrogen
   system.

- Serial interface

- Automatic of manual temperature compensation

- Automatic buffer detection

- Automatic detection of measuring value stability

- rH-measurements 

- Min-/Max value memory, Hold function

- Evaluation of probe quality

- Battery and d.c. operation

- device can be used as thermometer, too

- serial interface, device can be connected to bus system (up to 5 devices can be connected to one PC-interface)

 

GMH3530

 

GMH 3530 without accessories1)

GMH 35 ES additional set2)

1) pH-probe, temperature probe, redox probe calibration access., etc. please order separately or as additional set.

2) consisting of: pH-electrode GE 1OOBNC, temperature probe GTF 401 (Pt100 4-wire), case GKK 3500 and GAK 1400

 

Specification:

 
Meas. range:    Temperature:             -100.0 to +250.0°C or -148.0 to +482.0°F
   pH:                              0.00 to 14.00 pH
   Redox (ORP):           -1,999 to + 1,999 mV.
                                       for hydrogen system (DIN38404): -1,792 to +2,207mVH
   
rH: (GMH3530 only)    0.0 to70.0 rH
Accuracy: (device)  (±1 digit at nominal temperature)
    Temperature:         ±0.2°C (-20 to +80°C), otherwise ±0.4°C
    pH:                          ±0.01 pH
    Redox (ORP):        ±0.1 % FS (mV resp. mVH)
    rH:                        ±0.1 rH
Sensor connections:     Temperature:     4-pin screened Mini-DIN-socket.
                                for Pt100 4-wire (2-wire connection possible)
     pH,Redox:         BNC-socket
Input resistance:  (pH, Redox) 1012 Ohm
Display:  2 four-digit LCDs (12.4 mm or 7 mm high) for pH, redox and temperature, min./max values, hold function, etc. as well as additional functional arrows.
Working temperature:  0 to +50°C
Relative humidity:  0 to +95% r.h. (not condensing)
Storage temperature:  -20 to +70°C
Interface:  serial interface (3.5 mm jack connector), direct connection to RS232 interface of a PC via electrically isolated interface adapter GRS 3100 or GRS 3105 resp. via interface adapter USB 3100 to USB-interface
Min-/Max-value memory:  max. and min. values will be memorized.
Hold function:  By pressing a button, the current meas. value will be memorized.
Push buttons:  6 membrane keys for ON/OFF-switch, selection of meas. mode, 
        min- and max-value memory, hold-function, calibration etc.
Power supply:  9V-battery, Type IEC 6 F 22 (included) as well as additional d.c. connector 
        (internal pin diameter 1.9 mm) for external 10.5-12V direct voltage supply. 
        (suitable power supply: GNG 10/3000).
Low battery warning:  'bAt'
Power consumption:  approx. 3 mA
Automatik-Off-function:  Device will automatically be switched off, if no key is pressed
        /no interface communication takes place for the time of the power-off delay. 
        The power-off delay can be set to values between 1 and 120 min.; it can be completely deactivated.
Dimensions (device):  142 x 71 x 26 mm (H x W x D) 
       
impact resistant ABS plastic housing, membrane keyboard, transparent panel. 
        Front side IP 65, integrated pop-up clip for table top or suspended use.
Weight:  approx. 155 g
automatic temperature compensation:  Automatic temperature comp. (ATC) if temperature probe 
        is plugged in and operating mode is "pH". Manual temperature input if no probe connected.
pH-calibration:  automatic buffer detection. Automatic compensation of temperature dependance of buffers.
        acceptable elektrode data:     Asymmetry: ±60 mV
                                                     Slope: 45 ... 62 mV/pH
        Sensor evalution depending on calibration results (10 to 100%), displayed by pressing a key

       opt. 2- or 3-point-calibration with bend of the characteristics for GREISINGER-Standard-buffers 
        (pH4.01, pH7.00, pH10.01),  Buffers acc. to DIN19266 (A,C,D,F,G) or manual buffer entry.
Redox-mesurement (ORP): You have two choices
                    "mV"     standard-Redox- bzw. mV-measurement
                    "mVH"  Temp. compensated conversion to hydrogen system acc. to DIN 38404 part 6, table 1 
                                    based on the standard redox electrode (e.g. GE 105 
                                    with Ag/AgCl system and 3 mol KCL) used.
 
rH-measurement:  Calculation of the rH value by means of a redox measuring 
        and by manually entering the pH-value. The pH-value can also be taken from a previous pH measurement.
Temperature measurements: Display of current value 12.4 mm high for thermometer mode.
Min-/Max- or Hold values can be displayed in the second 7 mm high display.
   

Accessories:

 
Compatible electrodes  
   
   





Device for measuring pH, redox and temperature, lose device - without any electrodes or accessories

Please order the following accessories separately:


  Please order furthermore separately:



= data sheet as *.pdf

= instruction manual as *.pdf

deutsche Beschreibung

Price of the basic article, German V.A.T. incl : EUR 169.00


The net price of the basic article  GMH 3530 is:  EUR 142.02 




News