Specification:
|
|
|
Measuring range: |
Oxygen concentration: 0.0 ... 100.0 % O2
(gaseous)
Oxygen partial pressure (GMH3691): 0 ... 1100 hPa O2
Temperature: -5.0 ... 50.0°C |
|
Accuracy (device): |
±0.1%
±1digit (O2-concentration)
±1 hPa ±1digit (O2-partial pressure)
±0.2°C ±1digit (temperature)
|
|
Sensor connection: |
6 pin screened
Mini-DIN socket
suitable sensor p.r.t.
electrodes (GGO 369 / GOO 369) |
|
Display: |
2 four-digit LCDs (12.4 mm and 7
mm high) for oxygen and temperature
and for min./max. value, hold
function, etc. as well as additional functional arrows |
|
Working temperature: |
0 to +50°C
|
|
Relative humidity: |
0 to +95% r.h. (not
condensing) |
|
Storage temperature: |
-20 to +70 °C
|
|
Interface: |
serial interface (3.5mm jack
connector),
direct connection to RS232 interface
of a PC via electrically isolated interface adapter
GRS
3100
or
GRS
3105 or connection to USB-interface via USB3100-adapter
|
|
Min-/Max-value memory: |
max. and min.
values will be memorized.
|
|
Hold function: |
by pressing a button the
current meas. value will be memorized.
|
|
Alarm: |
integrated limit detector for
min. or max.-alarm
|
|
Push buttons: |
6 membrane keys for ON/OFF
switch, selection of meas. range,
min- and max-value memory,
hold-function calibration etc. |
|
Power supply:
|
9V battery, type IEC 6 F 22 (included)
as well as additional d.c. adapter (internal pin diameter 1.9
mm)
for external 10-12 V direct voltage supply (suitable power
supply GNG 10/3000)
|
|
Power-Off-Function:
|
Device will be automaticially
switched off if no key is pressed/
no interface communication takes
place for the time of the power-off delay.
The power-off delay can be set to
values between 1 and 120 min. or deactivated.
|
|
Low battery warning: |
'bAt'
|
|
Power consumption: |
approx. 1.5 mA
|
|
Dimensions: |
142 x 71 x 26 mm (H x W x D)
impact-resistant ABS plastic housing, membrane keyboard, transparent
panel.
Front side IP65, integrated pop-up
clip for table top or suspended use |
|
Weight:
|
approx. 160 g (cpl. with battery) |
|
Temperature compensation: |
automatically
via temperature sensor integrated in probe housing |
|
Compensation of air pressure: |
the O2-concentration will be
compensated according to the abs. atmospheric pressure set (500 to 2000 hPa)
|
|
Calibration: |
1-point calibration: extremely simple quick
(calibration in atmospheric air (press button to compensate unit to 20.9
%)
2-point calibration:
first point at atmospheric air (20.9 %) and second point freely selectable |
|
Application: |
Wide range of application
for your home, job and hobby, e.g.: - Bio chemistry: Oxygen monitoring an breeding
chambers for cell cultures.
Monitoring of fermenting process fo fruits infermentation plants etc.
- Medicine: Monitoring of oxygen concentration in
respirators; checking of breathing, gmh369
monitoring of oxygen concentration in incubators, oxygen tents etc.
- Food technology: Monitoring of residual
oxygen in packages (e.g. coffee, tea, etc.).
Monitoring of oxygen content during production processes
- Safety technology, safety at work: Oxygen
monitoring in mines/pits, underground parking lots,
wine cellars,
cooling chambers, greenhouses or stores.
Oxygen
monitoring or alarm in case of danger of suffocation when working in tanks,wells
etc.
- Air conditioning and ventilation technolgy:
Oxygen measurements, air quality monitoring,
measuring of
oxygen concentration in enclosed air conditioning systems, etc.
- Sports: Checking of oxygen conent in compressed
air breathing apparetuses (diving, etc.)
oxygen
monitoring for gliding.
|
Air oxygen measuring-device with double display for oxygen and temperature, lose device WITHOUT electrode