air oxygen measurement with GOG-set

In general:

Manufacturers, trade and consumer ask for longer durability of  foods.

The modern conserving industrie solves this problem by an "atmospheric gas protection shield".

The protective atmosphere consist of the gases N2 and CO2....



The GMH 3691 with GOG-set can be used for the measurement of traces of the remaining oxygen

 

GMH3690GL

GMH 3691 mit GOG-Set                

scope of delivery:
Air oxymeter GMH 3691, portable pump with air tube, GOG- oxygen sensor with
insertion needle, spare insertion needle diameter = 0.9 mm, case GKK 3500
40 pcs. cell foam stickers, manual instruction

Functionality:

With a needle/cannula you can penetrate into the package. The pump sucks the gas from the protective atmosphere.                                                                                                                         In less then 10 sec. the remaining oxygen concentration can be read off.
 

Specification:

 
Measuring range: Oxygen concentration:  0.0 ... 100.0 % O2 (gaseous)
Oxygen partial pressure (GMH3691): 0 ... 1100 hPa O2
Temperature: -5.0 ... 50.0°C
Accuracy (device): ±0.1% ±1digit (O2-concentration)
±1 hPa ±1digit (O2-partial pressure)
±0.2°C ±1digit (temperature)
Sensor connection: 6 pin screened Mini-DIN socket
Display: 2 four-digit LCDs (12.4 mm and 7 mm high) for oxygen and temperature 
and for min./max. value, hold function, etc. as well as additional functional arrows
Working temperature: 0 to +50°C
Relative humidity: 0 to 95% r.h. (non-condensing)
Storage temperature: -20 to +70 °C
Interface: serial interface (3.5mm jack connector), 
direct connection to RS232 interface of a PC via electrically isolated interface adapter
GRS 3100 or GRS 3105 or connection to USB-interface via USB3100-adapter  
Min-/Max-value memory: max. and min. values will  be memorized.
Hold function: by pressing a button the current meas. value will  be memorized.
Alarm: integrated limit detector for min. or max.-alarm
Push buttons: 6 membrane keys for ON/OFF switch, selection of meas. range, 
min- and max-value memory, hold-function calibration etc.
Power supply: 9V battery, type IEC 6 F 22 (included)
as well as additional d.c. adapter (internal pin diameter 1.9 mm) 
for external 10-12 V direct voltage supply (suitable power supply GNG 10/3000)
Power-Off-Function: Device will be automaticially switched off if no key is pressed/
no interface communication takes place for the time of the power-off delay. 
The power-off delay can be set to values between 1 and 120 min. or deactivated.
Low battery warning: bAt'
Power consumption: approx. 1.5 mA
Dimensions: 142 x 71 x 26 mm (H x W x D) impact-resistant ABS plastic housing, membrane keyboard, transparent panel. 
Front side IP65, integrated pop-up clip for table top or suspended use
Weight: approx. 160 g (incl. with battery)
Temperature compensation: automatically via temperature sensor integrated in probe housing
Compensation of air pressure: the O2-concentration will be compensated according to the abs. atmospheric pressure set (500 to 2000 hPa)
Calibration: 1-point calibration: extremely simple quick
(calibration in atmospheric air (press button to compensate unit to 20.9 %)

2-point calibration:  first point at atmospheric air (20.9 %) and second point freely selectable
Application: Wide range of application for your home, job and hobby, e.g.:

- Bio chemistry: Oxygen monitoring an breeding chambers for cell cultures.
                          Monitoring of fermenting process fo fruits infermentation plants etc.

- Medicine: Monitoring of oxygen concentration in respirators; checking of breathing, 
                   monitoring of oxygen concentration in incubators, oxygen tents etc.   

- Food technology: Monitoring of residual oxygen in packages (e.g. coffee, tea, etc.).
                              Monitoring of oxygen content during production processes

- Safety technology, safety at work: Oxygen monitoring in mines/pits, underground parking lots, 
            wine cellars, cooling chambers, greenhouses or stores. 
            Oxygen monitoring or alarm in case of danger of suffocation when working in tanks,wells etc.

- Air conditioning and ventilation technolgy: Oxygen measurements, air quality monitoring, 
           measuring of oxygen concentration in enclosed air conditioning systems, etc.

- Sports: Checking of oxygen content in compressed air breathing apparatus (diving, etc.) 
              oxygen monitoring for gliding.

Further specification p.r.t. GMH 3691 and GGO 369S





Air oxygen measurement device for the measurement of traces of remaining oxygen in a protective atmosphere for foods.

Please order the following accessories separately:


  Please order furthermore separately:



= data sheet as *.pdf

= instruction manual as *.pdf

deutsche Beschreibung

Price of the basic article, German V.A.T. incl : EUR 667.00


The net price of the basic article  GMH 3691 GOG is:  EUR 560.5 




News