DIGITAL-PANEL-MOUNTED DISPLAY MODULES for all applications

- 2 temperature-modules (covering temperature ranges from -50 to  
   1150°C)

- 3 pressure modules for barometer, vacuum meter, manometer for
   absolute pressure, over/under pressure and pressure difference
    measurements. pressure range up to 10 bar

- one voltmeter module with 3 integrated voltage ranges

 

Common specification for all modules:

Display: 3 1/2-digit, 13mm high LCD-display (±1999 digit)

Scan rate: 3 meas./sec.

Nominal temperature: 20°C

Operating temperature: 0 to 50°C

Atomspheric Humidity: 0 to 85% r. h. (not-condensing)

Storage temperature: -10 to +70°C

Power consumption: 9-12V DC

Dimensions: 38 x 76 x 22 mm (H x W x D)

Panel cutout: 36+0.5 x 73.2+0.5 mm (H x W)

Panel thickness: max. up to 9.5mm
        snap-on frame protruding only 1 mm over front plate 
        - professional design, 3 mm thick anti-reflex screen


TEMPERATURE:

 

GPT 180

TEMPERATURE MODULE for semiconductor sensor KTY83-110

Meas. range: -50.0 ... +175.0°C

Resolution: 0.1°C

Accuracy: approx. 1% FS

Power consumption: approx. 1mA

Suitable Sensors: KTY 83-110

 

GPT 1155

TEMPERATURE MODULE for Thermocouple  NiCr-Ni (Type K)

Meas. range: -50 ... +1150°C

Resolution: 1°C

Accuracy: from -20 to +550 and 920 to 1150°C better than 1%
    550 to 920 better than 1.5%

Power consumption: approx. 0.35mA

Suitable Sensors: NiCr-Ni (type K)  & GTU 300/152 wire sensor with solgering pin plug

 

PRESSURE:

 

GPD 15 ABS

DIGITAL-BAROMETER-/VAKUUM METER-MODUL (sensor not included)

Meas. range: 0 ... 1100 mbar (hPa) absolute

Resolution: 1 mbar

Accuracy module: 1 mbar ± 1 digit

Accuracy sensor: (sensor not included in scope of supply)
        ±0,2% linearity and hysteresis; ±0.4% for temperature drift from 0 to 50°C
        (typ. values for sensors compensated to module)

Power consumption: approx. 3.5mA (Sensor included)

Suitable sensors: (please order separately)
        SCX 15 ANC
(pressure sensor, loose)
        SCX 15 ANC/D (pressure sensor with housing, 1m connection cable)       

(additional upcharge for double accuracy)

 

GPD 30 REL

DIGITAL-MANOMETER for over/under and pressure difference (Sensor not included)

Meas. range: -1000 ... 1999 mbar relative (referring to ambient pressure)

Resolution: 1 mbar

Accuracy module: 1 mbar ± 1 digit

Accuracy module: 1 mbar ± 1 digit

Accuracy sensor: (sensor not included in scope of supply)
        ±0,2% linearity and hysteresis; ±0.4% for temperature drift from 0 to 50°C
        (typ. values for sensors compensated to module)

Power consumption: approx. 3.5mA (Sensor included)

Suitable Sensors: (please order separately!)
   
     SCX 30 DNC (pressure sensor, loose)
         SCX 30 DNC/G (pressure sensor with housing, 1m connection cable) 

(additional upcharge for double accuracy)

 

GPD 150 REL

DIGITAL-MANOMETER for over/under and pressure difference (Sensor not included)

Meas. range: -1,00 ... 10,00 bar rel. (referring to ambient pressure)

Resolution: 0.01 bar

Accuracy module: 1 mbar ± 1 digit

Accuracy sensor: (sensor not included in scope of supply)
        ±0,2% linearity and hysteresis; ±0.4% for temperature drift from 0 to 50°C
        (typ. values for sensors compensated to module)

Power consumption: approx. 3.5mA (Sensor included)

Suitable sensors: (please order separately!)
    SCX 150 DNC (pressure sensor, loose)

 SCX 150 DNC/G (pressure sensor with housing, 1m connection cable)


    (additional upcharge for double accuracy)

 

 

Voltage:

 

GPV 220

DIGITAL-VOLTMETER, 
3 integrated voltage ranges - others can be realised by means of an external voltage divider (e.g. for mains voltage 230 V etc.)

Meas. range: integrated ±199.9mV, ±1999mV, ±19.99V
    (±199.9V or ±1999V can be realised by means of an external voltage divider)

Decimal point: any place selectable

Resolution: up to 100 µV

Input impedance: 100MOhm resp. 1MOhm

Accuracy: 0,1% ± 1 digit

T.C. value: 100 ppm / K

Power consumption: apptox. 100 µA only (approx. 3000 hours with normal 9V-battery)



DIGITAL-PANEL-MOUNTED DISPLAY MODULES for all applications
DIGITAL-MANOMETER for over/under and pressure difference (Sensor not included) Meas. range= -1.00 up to 10.00 bar relative


Please order separately:



= data sheet as *.pdf

= instruction manual as *.pdf

deutsche Beschreibung

Price of the basic article, German V.A.T. incl : EUR 43.70