Redox-measuring transducer
electrically isolated, 4 ...
20 mA
|

GRMU 2000 MP-VO: with on-site display |


|
Specification:
|
|
| Meas.
range: |
+ 2000 mV or
individually narrowed measuring ranges according to customer specification! |
|
Output signal: |
4-20 mA (2-wire - standard),
0 - 10 V (3-wire, optionally) |
| Accuracy: |
0.2 % |
| Electric
iaolation: |
output electrically isolated |
|
Auxiliary energy: |
12 ... 30 V DC
at Option 0 - 10 V: 18 ... 30
V DC |
| Permissible impedance: |
( bei 4 ... 20 mA): RA
(Ohm) = UV (V) - 14 / 0,02 A) |
|
Permissible load: |
(bei 0 - 10 V): RL
> 3000 Ohm |
|
Electrode: |
Redox-Elektrode GE 105 ist
nicht im Lieferumfang enthalten |
| Input resistance: |
1012 Ohm |
|
Electrode pin: |
Cinch-Socket (Standard)
Optionally BNC-Socket (please
specify on your order) |
| Option: |
On-site-display: ca. 10 mm
hohe, 3 1/2 digit LCD |
| Working temperature: |
0 ... +50
°C |
| Storage temperature: |
- 20 ... +70 °C
|
| Electric
connection: |
angular plug according to DIN 43650 (IP 65),
max. cross section of wire: 1.5
mm²
average of wire: 4.5 to 7 mm |
|
Housing: |
ABS (IP65) except for electrode-pin
(complete IP 65 upon request) |
|
Dimensions: |
82 x 80 x 55 mm (W x H x D) |
| Mounting: |
Via drilling for wall mounting (accessible
after removing top)
Fixing distance: 70 x 50
mm (W x H)
Fixing screws: max. shaft
diameter 4 mm
|
| |
|
|
Order example: |
|
| GRMU 2000 MP / BNC, VO: |
GRMU 2000 MP
with BNC electrode-pin and on-site display |
Redox-measurement transducer, galvanically isolated, 4 ... 20 mA (two lane standard) and 0 ... 10 V (three lane optional), basic price
Please order separately:
= data sheet as *.pdf
= instruction manual as *.pdf
deutsche Beschreibung
|