Categories



The complete product assortment of the GSG Geologie-Service GmbH

According to your requirements we are arranging together with
you the optimum system for your individual application
Please describe us your requirements, our team will contact you as soon as possible.

You are reaching us by e-mail: 
mail@geologie-service.de
or by:
Phone: +49 (0)931/30 40 8-0
Fax: +49 (0)931/99105 90



GTF 103 - Details

Home --> Devices for Switch Panels / Industry --> Measuring Transducer --> Temperature Measuring Transducer



 

Customized probes acc. to your requirements or standard design and accessories

(del. time from stock or 1 or 2 working days)

other design types please click here

 

1. GTF 103

sensor installation potential-free

Material sensor tube:

for Pt100/1000 = material V4A (1.4571)

for NiCr-Ni = Inconel 600

Available sensors (Standard): 1 x Pt100 / Pt 1000 (2-, 3- or 4-wire), 1 x NiCr-Ni
        (please specify type of sensor upon order)

Temperatures:     Pt 100 / Pt 1000 (standard): -50 ... +400 °C
                           NiCr-Ni: -200 ... +1150 °C

Tolerances:          Pt100 / Pt1000 (standard): class B
                            NiCr-Ni: max. class of accuracy 1

Sensor head:           max. 200 °C. For higher collar tube temperatures -> p.r.t. 1.10

 

Special designs: (partly against upcharges - please enquire)

1.1    GTF 103 as 1, but any sensor length: Please specify sensor tube on your order
                    (upcharge per beginning of 100 mm)   

1.2    GTF 103, as above,but any probe tube diameter (also available spaced in front for quick response time)

1.3    GTF 103, stainless steel sensor head

1.4    GTF 103, plastic sensor head

1.5    GTF 103, small sensor head (design-type DE) with PG9-cable glanding

1.6    GTF 103, without thread (Can be used as plug-in probe in connection with screw-type/immersion sleeve EST01
                            or with moveable stainless steel clamping ring glanding G 1/2" for accurate adjustment of run-down length on site)

1.7    GTF 103 with exchangeable measuring insert

1.8    GTF 103 / GKM with transducer GKM...P (for Pt 100) and output signal 3-20 mA
                    (please specify upon order)

1.9    GTF 103 / T12 with transducer T12, any sensor and electrically insulated output 4-20 mA
                    (please specify measuring range upon order)

1.10  GTF 103 with collar tube (for higher temperatures, as connection knob (no transducer)
                    can be subjected to temperatures of up to max 200 °C)
                    or for bridging of thick insulation layers.

 

Please specify length of collar tube upon your order

 

1.11  GTF 103 with double-Pt100 (FL = 100 mm)
         GTF 103 with double NiCr-Ni (FL = 100 mm)
            for extended length additional upcharge per beginning of 100 m

Please do not hesitate to contact us - we will be pleased to advise you and to find the optimum design for your requirements!

 

2. Immersion sleeve of stainless steel:

 

2.1  Immersion sleeve EST01 for all probes without thread

 

2.2  Immersion sleeve EST02 for all probes with a G 1/2"-thread

 

3. Clamping ring screw connection GKV st. steel

for all probes without thread

 

Type Outer thread Clamp. ring-diam.
Sensor-tube-diam.
Clampiang ring
GKV1 M8 x 1 1.5 mm teflon
GKV2 st.steel
GKV3 3.0 mm teflon
GKV4 st.steel
GKV5 G 1/4" 1.5 mm teflon
GKV6 st.steel
GKV7 3.0 mm teflon
GKV8 st.steel
GKV9 G 1/2" 6.0 mm teflon
GKV10 st.steel

 

4. Cable and Lines:

4.1    2-, 3- or 4-pole silicon cable (max. 200 °C) with teflon screenes wires (2-pole highly flexible)
            3- and 4-pole standard with 3 or 4x0.14² cross section, insulation 2xblue, 1xwhite or 2xblue, 2xwhite

4.2    as above, but cable insulated with glass silk, no stainless steel braiding 2-, 3- or 4-pole (max. 400 °C)

4.3   as above, but cable insulated with teflon, indiviudal wires insulated with teflon, 2-pole
             3- or 4-pople with additional cable screen

4.4    PVC-lines (max. 70 °C)

4.5    Compensation lines for NiCr-Ni (Typ K), 2-wire      
        - Silicon cable (max. 200 °C)
        - Teflon cable (250 °C) screened
        - Glass silk (max. 400 °C)
        - Thermo wire (can also be used as thermo couple) glass silk (max. 400 °C)
        - teflon screened twisted thermo wire, wire-diameter 0.2 mm (max. 250 °C)
        - Thermo-wire, with glass silk braiding, wire-diameter 0.2 mm (max. 400 °C)

 

 

5. Flat-pin connections, free from thermal e.m.f. type K (NiCr-Ni) and type S (PtRh-Pt):

 

 

Type Description, dimensions Measuring range Tolerance
Pt 100 / 1 Ceramic lamina, 2 x 2.3 x 0.6 mm -70 ... +500 °C B
Pt 100 / 2 Ceramic lamina, 2 x 2.3 x 0.6 mm -50 ... +500 °C 1/3 DIN
Pt 100 / 3 Ceramic lamina, 2 x 4 x 0.9 mm -196 ... +500 °C B
Pt 100 / 4 Wound design, diameter 2 x 15 mm -200 ... +600 °C B
Pt 100 / 5 TO92-housing -50 ... +150 °C B
Pt 1000 / 1 Ceramic lamina, 2 x 10 x 0.9 mm -50 ... +400 °C B
Pt 1000 / 2 TO92-housing -50 ... +150 °C B
KTY 10-6 2kOhm (25°C), TO92-housing -50 ... +150 °C
KTY 11-2A 2kOhm (25°C), TO92-Mini-housing -50 ... +150 °C
KTY 87-205 2kOhm (25°C), SOD103-housing -40 ... +110 °C
KTY 83-110 1kOhm (25°C), DO34-housing -50 ... +175 °C
KTY 84-130 1kOhm (100°C), DO34-housing -50 ... +300 °C

Other sensors upon request



Panel resistance thermometer Pt 100, basic price


= data sheet as *.pdf

deutsche Beschreibung

Price of the basic article, German V.A.T. incl : EUR 83.00


The net price of the basic article  GTF 103 is:  EUR 69.75 




News