GTF 55B - Details

Home --> pH- and Redox-Devices --> Special Accessories for pH-Meters

waterproof hand-held measuring device for pH/redox GMH 5530/GMH 5550 - Greisinger


waterproof hand-held measuring device for pH/redox

 


application:


  

  • measurement in water, fishkeeping, aquafarming
  • drinking water monitoring, process control,
    ground floor measuring
  • food production and monitoring
  • laboratory: medicine, pharmaceutics, chemistry
  • quality management

features:


  • waterproof (device and plug connections)
  • serial interface and analog output
  • data logger function
  • GLP-features (good laboratory practice)
  • robust and with good grip
  • silicone protection cover
  • big dual display
  • background lightning
  • high resolution (0.001 pH / 0.1 mV)

 


GMH 5530     


without accessories

GMH 5550    


with analog output and data logger, without accessories


 


general function description:

Min/Max value memory:

highest and lowest value measured are saved

auto-hold:

recognizes automatically a constant measuring value and freezes it

auto power off:

device is automatically switched off after a selected period
if unused (0 to 120 min., or deactivated)

additional display for
pH-electrode and battery:

bar graph display

 

low battery display:

"BAT"
 

automatic temperature
compensation:

There is an automatic temperature compensation (ATC) within
the range of 0°C to +105°C for operation mode "pH" and if
a temperature probe is connected.
Without connected probe the temperature can be input manually.
 

pH-calibration:

The used buffer is detected automatically.
The temperature probe dependency of the buffer is automatically
compensated.

permissible electrode data:

asymmetry:

+55 mV / slope: 45 to 62 mV / pH

The condition of pH-electrode is checked at each calibration.
1-, 2- or 3-point calibration with characteristics bend for
GREISINGER-standard-buffer, buffer to DIN 19266 or manual
buffer input.
 

redox-measurement (ORP):

2 possibilities:

"mV"

standard-redox- or mV-measurement

"mVH"

conversion to hydrogen systems according to
DIN38404 part 6
 

rH-measurement:

The rH-value is calculated from a redox-value measured and
a pH-value manually input .

 


Specification:
measuring range: ph: -2,000 pH to 16,000 pH
redox / mV: -2,000 mV to +2,000 mV
  -1,000.0 mV to +1,000.0 mV
temperature: -5.0°C to +150.0°C
  +23.0°F to +302.0°F
rH: 0.0 rH to 70.0 rH
accuracy: pH: +0.005 pH
redox / mV: +0.05 % FS (mV or mVH)
temperature: +0.2°C
rH: +0.1 rH
connections: pH, redox: BNC- female connector, compatible to standard BNC-plugs
and waterproof BNC-plugs,
additional banana-jack (4 mm) for separate reference electrode
input resistance 1012 Ohm
temperature: 2 banana-jacks (4 mm) for temperature probes (Pt1000 or NTC 10K)
interface/
supply:
4-pole bayonet female connector for serial interface and supply
(with USB 5100)
display: two 4 1/2-digit 7-segment-display (15 mm and 12 mm)
pH-calibration: automatically: 1-, 2- or 3-point calibration, GREISINGER-standard-buffer or
buffer to DIN 19266 (A, C, D, F, G)
manually: 1-, 2- or 3-point calibration
protection class: IP65 (housing and connections)
dimension: 160 x 86 x 37 (protection cover incl.)
weight: 250 g (battery and protection cover incl.)
housing: impact resistant ABS housing with pop-up clip
power supply: 2x AAA-batteries (in scope of delivery) power consumption <1.0 mA
battery life time: approx. 1,000 hours


 


functions:
  GMH 5530 GMH 5550
Min/Max value memory:

x


x

hold/ auto-hold:

x


x

auto power off:

x


x

low battery display "BAT":

x


x

display of condition of pH-electrode

x


x

background lightning:

x


x

period selectable (ON / OFF or 5 s to 2 min.)
automatic temperature compensation:

x


x

adjustable calibration intervals (GLP):

x


x

calibration memory (GLP):

-


x

analog output:

-

0-1 V, freely adjustable,
connection with 4-pole bayonet connector
resolution 13 bit, accuracy 0.05% at
nominal temperature
data logger:

-

with measuring point input
recording interval: 1 s to 1 h
recording period: 416 days at interval 1 h
value memory: cyclic: 10,000 data sets
singular: 1,000 data sets
real-time clock: -


x

Min/Max alarm: -

permanent monitoring of alarm boundaries
3 alarm conditions

off: alarm function inactive
on: alarm report via display,
integrated buzzer and
interface
no sound: alarm report only via
display and interface



Pt1000 temperature immersion probe for liquids, 1m PVC cable with two banana plugs for



= data sheet as *.pdf

deutsche Beschreibung

Price of the basic article, German V.A.T. incl : EUR 40.80