Temperature measuring transducer GTMU, completely with sensor
(constructions with measuring transducer, electrically isolated, for outdoor
applications as well as constructions without measuring transducer -
Greisinger electronic -
Temperature measuring probe
cpl. with Pt100 or NiCr-Ni (type K) sensor
General information:
At the GTMU you are able to select from 5 basic
constructions and 2 sensor types. So you have got the possibility to
adjust the system optimally to your requirements.
The constructions 1-4 are completely with sensor, measuring transducer incl,
readily calibrated and so ready for mounting and use.
At construction 5 the sensor is missing, which you are already possessing or
have to be ordered extra acc. to your wishes (please don't hesitate to
contact us).
Design 1
to be screwed in directly
Probe with thread "G"
Standard: G= 1/2" (= 1,27 cm), FL= 100mm, D=6mm
Design 2
for higher temperatures
Thread split from housing by collar tube HL
Standard: G= 1/2" (= 1,27 cm), HL= 50mm, FL= 100mm, D=6mm
Design 3
Room our outdoor probe
for direct wall mounting
Standard: FL= 50mm, D=3mm
Design 4
Channel probe
Probe mounted in the middle and vertical downwards
Standard: FL= 100mm, D=3mm
Design 5
for external probes
measuring transducer for already existing sensores
Pt100 or NiCr-Ni
resp. also then, if probe and housing have to be mounted separately
(e.g. due to very high ambient temperatures or if necessary due to the
construction
GTMU1
Design 1
GTMU2
Design 2
GTMU3
Design 3
GTMU4
Design 4
GTMU5
Design 5
GTMU/GITT
Electrically isolated measuring transducer
(design 1 to 5 - Pt100, Pt1000 or NiCr-Ni, only possible with output 4-20 mA)
GTMU/RT420
Measuring transducer for outdoor aplications
(possible sensors: Pt100, only possible with output 4-20 mA)
We also offer the sensors without the mounted measuring transducer as pure
temperature sensor.
The sensor is directly connected with the elbow plug at this construction:
GTU/-2R-OMU
beautiful room housing
(possible sensors Pt100 (4-wires), Pt1000 (4-wires)
GTMU-OMU1
Design 1
GTMU-OMU2
Design 2
GTMU-OMU3
Design 3
(Pt100: 4-wires, Pt1000: 4-wires, NiCr-Ni
(not potential-free); potential-free p.r.t. options
GTMU-OMU4
Design 4
(Pt100, 2-/3- or 4-wires, Pt1000 upon request, NiCr-Ni
(not potential-free); potential-free p.r.t. options
Specification:
Sensorelements:
resistance thermometer Pt 100, class B, or thermo couple NiCr-Ni (type K)
class 1
Measuring ranges:
Pt100: 0 to 100°C, 0 to 200°C, -50
to +50°C, -50 to +150°C
NiCr-Ni: 0 to 100°C, -50 to +150°C, -200 to +300°C, 0 to 600°C, 0 to 1,200°C OPTION:
any possible measuring range again surcharge
Accuracy electronics:
+ 0.2 % FS (Pt100) resp. + 0.2
% + 0.5 °C (NiCr-Ni)
(higher accuracies e.g.. by optionally
other measuring transducer(GITT01, RT420)
Output signal:
Standard: 4 - 20 mA (2-wires)
Optional: 0-1V, 0-2 V, 0-5 V,
0-10 V (3- or 4-wires) available (not at GITT01 and RT420)
Auxiliary energy:
Uv = 12 ... 30 V DC
(at 0-10 V: Uv = 18 ... 30 V DC) (at special constructions e.g. GTMU/GITT 8 ... 30 V)
Reverse voltage protection:
50 V permanently
Permissible impedance:
(at 4-20 mA) RA (Ohm) = Uv (V) - 12 / 0.02 A)
(with GITT and RT 420 p.r.t. to specifications there)
Permissible load:
RL (Ohm) >
3000 Ohm
Operating temperatures electronics:
0°C to + 70
°C (-40°C to +85 °C with .../RT420 and ../GITT)
Temperature coefficient:
0.01 % / °C
(Pt100), 0.05 % / °C (NiCr-Ni)
Storage temperature:
-20°C to +70 °C
Housing:
ABS (IP65)
Mounting:
with holes for wall mounting (accessible
after removal of cover)
Mounting distance: 70 x 50 mm (B x
H)
Fixing screws: max. shaft diameter 4 mm
Electrical connection:
Elbow plug acc. to DIN 43650 (IP
65)
Sensor connection:
(at design 5)
Pt100: 2- or 3-wires possible
NiCr-Ni: 2-wires
Introduction for sensor cable by PG7
Connection with board by screw clemp
Thread sizes "G":
Standard:
G 1/2" (= 1,27 cm)
Optional: G 1/4" (= 0,635 cm), G 3/8" (= 0,9525 cm), M 5, M 6, M 8, M 10, M 12
Probe tube:
Diameter "D": 3, 4, 5, 6 oder 8 mm
Length of probe tube "FL": standard length p.r.t. design, optionally
any length possible
Collar tube:
(only at design 2): HL ) please
note length required by you
Sensor installation:
Pt-sensors are generally installed
potential-free
NiCr-Ni sensors are generally not potential-free (sensor connected with
outer jacket)
OPTION: potential-free construction possible
urgently required informations for us are:
Construction, sensor element, measuring range, output signal, probe
specifications
If we don't have further information, the probe will be manufactured acc. to the
standardised specification
GTMU, design 1, Pt 100 DIN Kl. B, 0 ... 100 °C = 4 - 20 mA, G =
1/2" (= 1,27 cm), FL = 100 mm, D = 6 mm
GTMU, design 3, NiCr-Ni, 0 ... 1200 °C = 4 - 20 mA, FL = 50 mm, D = 3 mm
GTMU, design 5, Pt100, -50 ... +150 °C = 0-10V
Options:
-AV...
other output signal
(not possible with GITT and RT420)
-LACK
encapsulated PC board (for outdoor application, i.e. applcations where
codensation is possible)
-MB...
Option any possible measuring range (please not measuring range wished)
at option -AV..,-MB the surcharge has not to be paid at a minimum quantity
of 10 pcs. of equal design
- FL
Longer probe tube, upcharge for ach further beginning 100 mm
-HL
Longer collar tube, upcharge for ach further beginning 100 mm
-VO
on-site display (for output signal 4-20 mA, auxiliary energy Uv =
17 ... 30 V DC
-POT
Option: potential-free installed NiCr-Ni probe
-D
other probe diameter (without surcharge)
-G
other thread (upon request)
nice housing in several types of construction, GTMU without measuring transducer
(possible sensor connection: Pt100, 2-/ 3- or 4-wire, Pt1000 upon request, NiCrNi 2-wire),
basic price
works calibration certificate upon request
= data sheet as *.pdf
= instruction manual as *.pdf
deutsche Beschreibung
Price of the basic article, German V.A.T. incl
:
EUR
29.50
The net price of the basic article GTU/-2R-OMU
is:
EUR
24.79