GTU/-2R-OMU - Details

Home --> Devices for Switch Panels / Industry --> Measuring Transducer --> Temperature Measuring Transducer


Temperature measuring transducer GTMU, completely with sensor (constructions with measuring transducer, electrically isolated, for outdoor applications as well as constructions without measuring transducer -  Greisinger electronic -


Temperature measuring probe

cpl. with Pt100 or NiCr-Ni (type K) sensor

 

General information:

At the GTMU you are able to select from 5 basic constructions and  2 sensor types. So you have got the possibility to adjust the system optimally to your requirements.
The constructions 1-4 are completely with sensor, measuring transducer incl, readily calibrated and so ready for mounting and use.
At construction 5 the sensor is missing, which you are already possessing or have to be ordered extra acc. to your wishes (please don't hesitate to contact us).
 

Design 1

to be screwed in directly

Probe with thread "G"

Standard: G= 1/2" (= 1,27 cm), FL= 100mm, D=6mm

 

Design 2

for higher temperatures

Thread  split from housing by collar tube HL

Standard: G= 1/2" (= 1,27 cm), HL= 50mm, FL= 100mm, D=6mm

Design 3

Room our outdoor probe

for direct wall mounting

Standard: FL= 50mm, D=3mm

 

 

Design 4

Channel probe


 

Probe mounted in the middle and vertical downwards

Standard: FL= 100mm, D=3mm

 

 

Design 5

for external probes

measuring transducer for already existing sensores Pt100 or NiCr-Ni
resp. also then, if probe and housing have to be mounted separately
(e.g. due to very high ambient temperatures or if necessary due to the construction

 

GTMU1                        Design 1
GTMU2                       Design 2
GTMU3                       Design 3
GTMU4                      Design 4
GTMU5                        Design 5
GTMU/GITT             Electrically isolated measuring transducer
(design 1 to 5 - Pt100, Pt1000 or NiCr-Ni, only possible with output  4-20 mA)
GTMU/RT420            Measuring transducer for outdoor aplications
(possible sensors: Pt100, only possible with output 4-20 mA)

 
We also offer the sensors without the mounted measuring transducer as pure temperature sensor.
The sensor is directly connected with the elbow plug at this construction:

 

GTU/-2R-OMU         beautiful room housing
(possible sensors Pt100 (4-wires), Pt1000 (4-wires)
GTMU-OMU1            Design 1 
GTMU-OMU2            Design 2
GTMU-OMU3            Design 3 
(Pt100: 4-wires, Pt1000: 4-wires, NiCr-Ni 
(not potential-free); potential-free p.r.t. options
GTMU-OMU4   Design 4
(Pt100, 2-/3- or 4-wires, Pt1000 upon request, NiCr-Ni 
(not potential-free); potential-free p.r.t. options

 

Specification:

 
Sensorelements:  resistance thermometer Pt 100, class B,  or thermo couple NiCr-Ni (type K) class 1
Measuring ranges: Pt100: 0 to 100°C, 0 to 200°C, -50 to +50°C, -50 to +150°C
NiCr-Ni: 0 to 100°C, -50 to +150°C, -200 to +300°C, 0 to 600°C, 0 to 1,200°C

OPTION: any possible measuring range again surcharge

Accuracy electronics: +0.2 % FS (Pt100) resp. +0.2 % +0.5 °C (NiCr-Ni)  
(higher accuracies e.g.. by optionally other measuring transducer(GITT01, RT420)
Output signal: Standard: 4 - 20 mA (2-wires)
Optional: 0-1V, 0-2 V, 0-5 V, 0-10 V (3- or 4-wires) available (not at GITT01 and RT420)
Auxiliary energy: Uv  = 12 ... 30 V DC (at 0-10 V: Uv = 18 ... 30 V DC) (at special constructions e.g. GTMU/GITT 8 ... 30 V)
Reverse voltage protection: 50 V permanently
Permissible impedance: (at 4-20 mA) RA (Ohm) = Uv (V) - 12 / 0.02 A)
(with GITT and RT 420 p.r.t. to specifications there)
Permissible load: RL (Ohm) > 3000 Ohm
Operating temperatures electronics: 0°C to + 70 °C (-40°C to +85 °C with .../RT420 and ../GITT)
Temperature coefficient:  0.01 % / °C (Pt100), 0.05 % / °C (NiCr-Ni)
Storage temperature: -20°C to +70 °C
Housing: ABS (IP65)
Mounting: with holes for wall mounting (accessible after removal of cover)
Mounting distance: 70 x 50 mm (B x H)
Fixing screws: max. shaft diameter 4 mm
Electrical connection: Elbow plug acc. to DIN 43650 (IP 65)
Sensor connection: (at design 5)
Pt100: 2- or 3-wires possible
NiCr-Ni: 2-wires
Introduction for sensor cable by PG7
Connection with board by screw clemp
Thread sizes "G": Standard: G 1/2" (= 1,27 cm)
Optional: G 1/4" (= 0,635 cm), G 3/8" (= 0,9525 cm), M 5, M 6, M 8, M 10, M 12
 
Probe tube: Diameter "D": 3, 4, 5, 6 oder 8 mm
Length of probe tube "FL": standard length p.r.t. design, optionally any length possible
 
Collar tube: (only at design 2): HL ) please note length required by you
Sensor installation: Pt-sensors are generally installed potential-free
NiCr-Ni sensors are generally not potential-free (sensor connected with outer jacket)
OPTION: potential-free construction possible

 

Order examples:

urgently required informations for us are:
Construction, sensor element, measuring range, output signal, probe specifications
If we don't have further information, the probe will be manufactured acc. to the standardised specification

GTMU, design 1, Pt 100 DIN Kl. B, 0 ... 100 °C = 4 - 20 mA, G = 1/2" (= 1,27 cm), FL = 100 mm, D = 6 mm
GTMU, design 3, NiCr-Ni, 0 ... 1200 °C = 4 - 20 mA, FL = 50 mm, D = 3 mm
GTMU, design 5, Pt100, -50 ... +150 °C = 0-10V

 

Options:

 
-AV... other output signal
(not possible with GITT and RT420)
-LACK encapsulated PC board (for outdoor application, i.e. applcations where codensation is possible)
-MB... Option any possible measuring range (please not measuring range wished) 
at option -AV..,-MB the surcharge has not to be paid at a minimum quantity of 10 pcs. of equal design
- FL Longer probe tube, upcharge for ach further beginning 100 mm
-HL Longer collar tube, upcharge for ach further beginning 100 mm
-VO on-site display (for output signal 4-20 mA, auxiliary energy Uv = 17 ... 30 V DC
-POT

Option: potential-free installed NiCr-Ni probe

-D other probe diameter (without surcharge)
-G other thread (upon request)


 




nice housing in several types of construction, GTMU without measuring transducer
(possible sensor connection: Pt100, 2-/ 3- or 4-wire, Pt1000 upon request, NiCrNi 2-wire), basic price

  • works calibration certificate upon request